This site is intended for healthcare professionals
Journals
  • Home
  • /
  • Journals
  • /
  • Primary Hyperoxaluria
  • /
  • Plasma oxalate levels in primary hyperoxaluria typ...
Journal

Plasma oxalate levels in primary hyperoxaluria type I show significant intra-individual variation and do not correlate with kidney function

Read time: 1 mins
Published:30th Jun 2020
Author: Hillebrand P, Hoppe B.
Availability: Pay for access, or by subscription
Ref.:Pediatr Nephrol. 2020 Jul;35(7):1227-1233.
DOI:10.1007/s00467-020-04531-5
Plasma oxalate levels in primary hyperoxaluria type I show significant intra-individual variation and do not correlate with kidney function


Background:
Primary hyperoxalurias are rare diseases with endogenous overproduction of oxalate, thus leading to hyperoxaluria, hyperoxalemia, urolithiasis, and/or nephrocalcinosis and eventually early kidney failure. Plasma oxalate (POx) is an important diagnostic parameter in clinical studies on primary hyperoxaluria (PH). This is especially the case in kidney failure, where urinary parameters are no longer suitable. We aimed to evaluate whether POx would be an adequate endpoint for clinical studies in PH patients with stable kidney function. In addition, the correlation of POx to serum creatinine (SCr) and calculated glomerular filtration rate (eGFR) was examined.

Methods: We retrospectively analyzed follow-up of individual POx values over time, as well as POx correlation to SCr, eGFR, and vitamin B6 (VB6), a common therapeutic in PH1. Results from 187 blood samples taken between 2009 and 2017, during routine laboratory evaluations from 41 patients with PH1 who had neither undergone dialysis nor transplantation, were evaluated.

Results: Negligibly low correlation coefficients (CCs) between POx vs. SCr (CC = -0.0950), POx vs. eGFR (CC = -0.1237), and POx vs. VB6 (CC = 0.1879) were found, with the exception of CKD stage 3a patients, who showed a positive correlation (CC of - 0.7329, POx vs eGFR). The intra-individual analysis of POx over time showed a high fluctuation of POx values.

Conclusion: We conclude that POx has a limited validity as a primary endpoint for clinical studies in PH1 patients with stable kidney function. In addition, it does not correlate to SCr and eGFR in this group of patients.


Read abstract on library site Access full article