Sterile Cord Blood Collection Unit (MSC127D)

Read time: 1 mins
Marketing start date: 26 Mar 2025

Summary of product characteristics


Indications And Usage

INDICATIONS AND USAGE MSC127D - For collection of up to 250 mL of umbilical cord blood. Use aseptic technique.

Description

MACO BIOTECH Collection - Sterile Cord Blood Collection Unit (MSC127D) The MSC127D Sterile Cord Blood Collection Unit consists of 300 mL collection bag containing 27 mL of Anticoagulant Citrate Phosphate Dextrose Solution USP (CPD), a 40 mL rinsing bag containing 8 mL of CPD and two 12 gauge needles with a protective shield (SECUVAM) for the used needle. Sterile, non-pyrogenic fluid path. Sterilized by steam. Rx only . This product is not made with natural rubber latex.

Warnings

WARNINGS Avoid contact with sharp objects. Do not irradiate collected cord blood or components. Making multiple punctures of the umbilical cord to increase collection volume may increase the risk of contamination.

Effective Time

20171221

Version

3

Spl Product Data Elements

Sterile Cord Blood Collection Unit (MSC127D) Anticoagulant Citrate Phosphate Dextrose Solution SODIUM CITRATE ANHYDROUS CITRIC ACID DEXTROSE MONOHYDRATE ANHYDROUS DEXTROSE CITRIC ACID MONOHYDRATE ANHYDROUS CITRIC ACID SODIUM PHOSPHATE, MONOBASIC, DIHYDRATE PHOSPHATE ION

Application Number

BN125552

Brand Name

Sterile Cord Blood Collection Unit (MSC127D)

Generic Name

Anticoagulant Citrate Phosphate Dextrose Solution

Product Ndc

14498-003

Product Type

HUMAN PRESCRIPTION DRUG

Route

INTRAVENOUS

Package Label Principal Display Panel

LABELS Collection Bag Label Overwrap Label REF MSC127D CollectionBagLabel OverwrapLabel

Instructions For Use

INSTRUCTIONS FOR USE Carefully Read All the Instructions Before Use Representative Product Drawing I. PREPARATION Before use, verify the integrity of the collection unit (overwrap, outlet ports, tubing...). Only contents inside the inner wrap are sterile and acceptable for use in a sterile field if pouch is unopened and undamaged. II. COLLECTION PROCEDURE Close all clamps 3A, 3B and 3C (clamp 9 should remain open). After clamping and sectioning of the umbilical cord, place the collection bag on a mixer and perform a venipuncture at lower end of the umbilical cord with first needle 1A. Note : Umbilical venipunctures can be done before or after the expulsion of the placenta according to your local procedures. 3. Open clamps 3A and 3C. 4. Stimulate cord blood flow by massaging the cord from the top downward to increase volume of collection. 5. When collection is completed, close clamps 3A and 3C. 6. Remove needle 1A and slide down SECUVAM 2A (needle protector) over needle 1A. 7. If necessary, perform a second umbilical venipuncture on the upper part of the umbilical cord (near the mother). [See Warnings]: a. Open clamps 3B and 3C. b. Perform venipuncture on the umbilical cord using other needle 1B. c. When collection is completed, close clamps 3B and 3C. d. Remove needle 1B and slide down SECUVAM 2B (needle protector) over needle 1B. III. RINSING OF COLLECTION LINE Open clamp 3C. Snap the break-away cannula on top of rinsing bag 6. Roll up bag 6 on itself to empty 8 mL of anticoagulant (CPD) in the tubing to push the cord blood remaining in the tubing into the collection bag. Do not strip the tubing. Close clamp 3C. Proceed to section V END OF COLLECTION if collection volume is less than 200 mL. For collection volumes greater than 200 mL, proceed to section IV ADDITION OF ANTICOAGULANT INTO THE COLLECTION BAG. IV. ADDITION OF ANTICOAGULANT INTO THE COLLECTION BAG Use this step only for collection volumes greater than 200 mL. Seal the tubing above the Y junction 5. Move clamp 3C near to Y junction 5. Using a blood stripper, strip the tubing from Y junction 5 towards the collection bag 8 expelling the anticoagulant in the tubing into collection bag 8. Repeat this operation 3 times. Mix collection bag 8. Close clamp 3C. Proceed to section V END OF COLLECTION. V. END OF COLLECTION Close clamp 9 to secure th collection. Seal the tubing between clamp 9 and collection bag 8. Fill in collection volume and CPD volume on the collection bag label. The amount of CPD is as follows: a. 27 mL - if no additional CPD is added. b. 35 mL - if additional 8 mL CPD from rinsing bag is added to the collection bag as directed in section IV. 4. For optimal cord blood quality, maintain the cord blood at an ambient temperature (18-26°C / 64.4-78.8°F) or cold temperature (4-12°C / 39.2-53.6°F). VI. CONTACT INFORMATION Manufactured for United States of America (U.S.A.) and Canada by Maco Productions Polonia, Sp. z o.o. ul. Szwajcarska 22, 54-405 Wroclaw, POLAND +48 71 37 60 110 For consumer information contact: For the U.S.A.: Distributed by Uneklo USA, Inc. dba Macopharma USA 3075 Breckinridge Boulevard, Suite 405, Duluth, GA 30096, USA (770) 270-6867 For Canada: Distributed by Macopharma Canada 1200 McGill College, Suite 1715, Montreal (Quebec) H3B 4G7 (514) 866-2222 VII. REFERENCES Pope, B. Mitsakos, K., Bilgin, A., Hokin, B. and Grant, R.: Predicting overall viability of cord blood harvests. Transfusion 2012:52:1079-1085 Salge-Bartels U. Huber. M, Kleiner K, Volkers P, Seitz R, Heiden M: Evaluation of Quality Parameters for Cord Blood Donations, Transfus Med Hemother 2009; 36:317-324 Prof. Dr. Kogler, Jose Carreras CBB, medical center, University of Duesseldorf: General information on the institution and the production facility of the Jose Carreras Cord Blood Bank. 2014 RepresentativeProductDrawing.jpg

How Supplied

HOW SUPPLIED MSC127D Sterile Cord Blood Collection Unit contains: 300 mL collection bag containing 27 mL CPD 40 mL rinsing bag contaning 8 mL CPD 2-12 gauge needles with a protective shield (SECUVAM) for used needle Graduation label as visual aid to approximate the volume

Precautions

PRECAUTIONS DO NOT use if the overwraps or bags show any signs of alteration. This is a single use sterile kit: under no circumstances should it be reused. For optimal cord blood quality it is recommended to maintain the cord blood at an ambient temperature (18-26°C / 64.4-78.8°F) or cold temperature (4-12°C / 39.2-53.6°F) and process within 48 hours of collection. 1,2,3 If the collection volume is less than 60 mL, the cord blood should be processed withing 24 hours of collection.

Learning Zones

The Learning Zones are an educational resource for healthcare professionals that provide medical information on the epidemiology, pathophysiology and burden of disease, as well as diagnostic techniques and treatment regimens.

Disclaimer

The drug Prescribing Information (PI), including indications, contra-indications, interactions, etc, has been developed using the U.S. Food & Drug Administration (FDA) as a source (www.fda.gov).

Medthority offers the whole library of PI documents from the FDA. Medthority will not be held liable for explicit or implicit errors, or missing data.

Drugs appearing in this section are approved by the FDA. For regions outside of the United States, this content is for informational purposes only and may not be aligned with local regulatory approvals or guidance.